Put the units beside every number

An impact-driver listing can show torque, rotational speed and impact rate close together. These numbers describe different things. Comparing whichever number looks largest can turn an accessory or control decision into a misleading performance ranking.

Make three separate fields when comparing tools: torque with its unit, rotational speed with its stated conditions, and impact rate. Keep the exact model beside each entry. This guide explains how to read those fields; it does not establish a winner or supply tightening instructions for a particular fastener.

Inch-pounds and foot-pounds are different scales

A pound-inch and a pound-foot express torque using different length units. There are twelve inches in a foot, so divide a torque expressed in inch-pounds by twelve to express the same quantity in foot-pounds. Do not compare the bare numbers before doing that conversion.

For a concrete specification example, the Makita XDT13Z record lists a maximum torque of 1,500 inch-pounds. The arithmetic equivalent is 125 foot-pounds. That is a conversion of its published figure, not an independently measured output or a promise that it will deliver a particular torque in your assembly.

Converting units changes the representation, not the evidence. It does not turn a manufacturer’s maximum claim into a tested fastening result, nor make two tools with similar converted numbers equivalent for every application.

A maximum rating is not a selectable target

The Bosch GDR18V-1400 manual lists a maximum torque of 1,400 inch-pounds. Its tightening section explains that achieved torque depends on the impacting duration and joint factors, including fastener hardness, washers, joined material and surface lubrication.

Those qualifications matter more than a small difference between headline figures. A listed maximum is not evidence that the driver automatically stops at the tightening requirement for your fastener. Nor is it a guarantee that the same result occurs in different materials or joints.

If an assembly has a specified tightening requirement, obtain the appropriate instructions and verification method for that assembly. This article provides no target torque for wheels, structural connections or other specific applications, and no impact-duration recipe to achieve one.

RPM and IPM should stay in separate columns

RPM is rotational speed; IPM is impact rate. Makita lists no-load variable speed and impacts per minute separately for XDT13Z. Bosch likewise separates no-load speed from impact rate in its specification table. Neither value should be renamed torque or treated as a measurement of completed jobs.

Keep the no-load qualifier when recording a speed. A maximum unloaded rate does not establish the speed under your fastening load. An impact-rate figure also does not prove that a tool will tighten a screw faster than another model under common conditions; that would need an appropriate comparative test.

Check what the controls actually offer

Once the units are clear, examine the control arrangement separately. Does the driver offer variable trigger speed, selectable power ranges or a documented application mode? A feature description is more useful when it addresses a task you can identify.

Our single-setting versus multi-mode guide covers that control decision. The impact-driver package guide addresses whether you need a kit or a bare tool. Neither question can be answered by the torque number alone.

Before buying, check the exact tool, accessory connection and application guidance, then compare like units and conditions. FindItWise has not measured these tools’ torque, speed or fastening accuracy. The examples illustrate specification reading rather than a recommendation to buy the larger number.

Before choosing a kit, check the exact model number, compatible battery and charger, and the seller’s included items.
Check the exact kit and its included items before purchasing.

Common questions

Does 1500 inch-pounds mean 1500 foot-pounds?

No. Dividing by twelve gives 125 foot-pounds as a unit conversion of the stated value, not a measured fastening result.